Toolkit · Layout & Drawings

Layout & Drawings

Enter a building size or load a site survey and fit-out workbook, choose the trucks that will work the aisles, and get an indicative 3D racking layout, dimensioned PDF and DXF drawings, storage options and indicative supply costs.

Building drawing: upload a DXF, PDF or image so the layout fits the building, columns and doors from it (stored in the project for every toolkit)

1. Building

2. Trucks for the aisles

Aisle widths are typical planning values, measured clear, rack face to rack face. Lift heights are typical planning caps. Confirm both with the truck supplier before you order racking or trucks.

3. Site survey optional, for exact drawings

Site survey inputs, template and uploads

Enter the internal clear sizes in millimetres, or upload a completed Excel or CSV workbook. The workbook has a sheet for each survey section plus a Requirements / fit-out brief, where the client states what they want built (positions needed, trucks, mezzanine, shelving, constraints). All coordinates are offsets from the survey datum (default: internal corner at grid A/1). You can also try a DXF of the building outline (best-effort — after import you can confirm or pick the datum). A filled example is available if you want to see a worked 90 × 60 m building. Planning-grade only, not a structural or certified design.

Survey datum

All X/Y values on this form and in the template are millimetre offsets from this datum. Heights are relative to the datum level. The default is the internal corner at grid A/1, X = 0, Y = 0.

Column grid

Doors: wall is south (y = 0 on the datum X axis, typically the dock wall), north, east or west. Offset is measured from the datum along that wall. Zones are rectangles (office, plant, no-go, marshalling, sprinkler) with x, y from the datum. Door opening heights are relative to the datum level (sill assumed at the datum unless you note otherwise).

DXF import is best-effort and client-side only. It looks for LWPOLYLINE or LINE to form a rectangular outline, and CIRCLE, INSERT or small closed polylines for columns. Binary DXF, blocks, non-rectangular buildings and most layer conventions are not fully supported. After a DXF is read, confirm or pick the datum (default: minimum X and minimum Y). Geometry is then translated so the datum is at 0, 0. Always check the result against the survey.

4. Mezzanine, shelving and storage options

Planning-grade typical values only. Confirm aisle, lift, density, deck load and fire travel with the truck, racking and mezzanine suppliers. Drawings are not a structural or fire-engineering design.

Mezzanine, shelving and bulk inputs
Floor joints (optional planning check)

Leave the spacing blank and no joint check runs. With spacings entered, the racking run start, bay start and aisle width (up to +100 mm) are adjusted so no upright baseplate sits on a joint, no VNA wheel track runs along a joint and no joint is within the guide-wire clearance of a VNA aisle centreline. Unavoidable clashes are shown in red. Planning check only: the racking supplier and flooring contractor confirm.

5. Order data optional

Download sample data file · Sample with weights · Columns recognised: SKU, quantity/units, pallets, cases, units per case, cases per pallet, item length/width/height in mm (used to send small parts to shelving/mezzanine), order lines, picks per day, and optional unit weight (kg) / case weight (kg) for mezzanine floor loading and rack beam checks. Blank weights use a stated default density of 250 kg/m³ (flagged).

Data insights and the ranked storage recommender appear below the drawing once data is loaded.

Advanced: small-parts thresholds

Dimensioned drawing

Planning-grade plan, based on the measurements you entered or uploaded, set out from the survey datum. North is a placeholder (into the building from the dock wall unless you note otherwise). Scale is stated in the title block. Ordinates are running dimensions from the datum. A setting-out table of key X/Y offsets from the datum is listed below and on the A3 PDF.

Planning-grade only — not a certified drawing. Quick Look uses simplified rules of thumb (standard 1.2 × 1.0 m pallets, a storage-options catalogue of typical planning values, tote shelving and a simple steel mezzanine, and typical planning aisle and lift values for the selected truck). Storage densities, selectivity, FIFO/LIFO, lane depths and automated footprints are typical planning figures, not brand claims and not a quotation. Drawings are based on the measurements you supply. They are not construction, structural, fire-engineering or building-regulations drawings, and they are not a racking installation design. They do not check floor loading, slab flatness, sprinklers, MHE guidance or manufacturer clearances. Verify all dimensions on site, and confirm aisle width, transfer aisles, guidance and lift height with the truck and racking suppliers, before ordering racking or trucks. Aisle widths are shown clear, rack face to rack face.

Want a full warehouse design?

Specialists can turn this sketch into a validated, data-driven design.